Reverse Osmosis
SYS-01High-recovery RO skids for process water and boiler feed, engineered around your feed analysis.
- Typical duty
- 5–100 m³/hr
- Recovery
- 60–75%
Every system here is designed, fabricated and commissioned by ENE Fluidtek — sized from your feed water analysis rather than a catalogue plate. Follow any of them into the detail.
High-recovery RO skids for process water and boiler feed, engineered around your feed analysis.
Two-bed and mixed-bed DM plants for high-purity process and utility water.
Single and twin softeners to protect boilers and CIP from hardness.
Pressure sand and multi-grade filters for turbidity and iron reduction ahead of RO.
Aeration-cum-filtration units for borewell feed with dissolved iron.
Chemical dosing skids for antiscalant, coagulant and pH correction.
A real plant is a chain: filtration and softening protect the membranes, dosing holds the chemistry, and the RO or DM delivers the quality your process needs. We design the whole chain, not a single box.
Media filtration and iron removal clean the feed; softening pulls the hardness that would scale the stages downstream.
Dosing systems meter antiscalant, coagulant and pH correction so the treatment stages see the water they were designed for.
RO or demineralisation delivers the final quality, monitored and cleaned on condition rather than on a calendar.