Systems / Technologies

Six treatment trains, engineered to your water

Every system here is designed, fabricated and commissioned by ENE Fluidtek — sized from your feed water analysis rather than a catalogue plate. Follow any of them into the detail.

Reverse osmosis skid with stainless membrane vessels on a blue frame

Reverse Osmosis

SYS-01

High-recovery RO skids for process water and boiler feed, engineered around your feed analysis.

Typical duty
5–100 m³/hr
Recovery
60–75%
Read the detail
Two blue demineralisation vessels with pipework in a plant room

Demineralisation

SYS-02

Two-bed and mixed-bed DM plants for high-purity process and utility water.

Type
Two-bed / mixed-bed
Regeneration
4% HCl / NaOH
Read the detail
Water softener vessel beside a blue control cabinet

Water Softener

SYS-03

Single and twin softeners to protect boilers and CIP from hardness.

Vessel
1000–1400mm
Media
Ion-exchange resin
Read the detail
End view of a pressure sand filter vessel

Media Filter

SYS-04

Pressure sand and multi-grade filters for turbidity and iron reduction ahead of RO.

Typical duty
10–80 m³/hr
Media
Sand / anthracite
Read the detail
Aeration-cum-filtration iron removal unit with pipework

Iron Removal

SYS-05

Aeration-cum-filtration units for borewell feed with dissolved iron.

Feed Fe
up to 8 mg/L
Effluent
<0.3 mg/L
Read the detail
Chemical dosing skids with metering pumps in a plant room

Dosing System

SYS-06

Chemical dosing skids for antiscalant, coagulant and pH correction.

Pumps
2x metering
Calibration
Column option
Read the detail

Rarely one train, usually a
sequence

A real plant is a chain: filtration and softening protect the membranes, dosing holds the chemistry, and the RO or DM delivers the quality your process needs. We design the whole chain, not a single box.

Pretreatment

Media filtration and iron removal clean the feed; softening pulls the hardness that would scale the stages downstream.

Chemistry

Dosing systems meter antiscalant, coagulant and pH correction so the treatment stages see the water they were designed for.

Separation

RO or demineralisation delivers the final quality, monitored and cleaned on condition rather than on a calendar.